Skip to content
Effectuez une recherche pour en savoir plus sur les produits et solutions InterSystems, les offres d'emploi, etc.

Advisory: Slow DELETE query during Health Insight data ingestion

March 23, 2020 – Advisory: Slow DELETE query during Health Insight data ingestion

InterSystems has corrected a defect affecting the population of Health Insight data.

This problem exists for:

  • HealthShare Health Insight customers upgrading from 15.03 to 2018.1 or above.

An issue was reported by a customer upgrading from Health Insight 15.03 to Health Insight 2019.1.  Their Health Insight instance had over 227 million records in the HSAA.Observation Table, whereas the HSAA.Outcome table was empty. The delete query was taking an average of 67 seconds (to delete zero records). This resulted in a large queue on the HSAA.TransferSDA3.Operation.Transfer component that was processing very slowly, causing Health Insight data ingestion to be slowed.

An Ad hoc software fix is available to correct this issue.

The correction for this defect is identified as AK1005 and will be included in all future product releases starting with Health Insight 2019.1.1. It is also available via Ad hoc change file (patch) or full kit distribution from the Worldwide Response Center (WRC).

If you have any questions regarding this advisory, please contact the WRC.

RELATED TOPICS

Latest Alerts & Advisories

17 Apr 2025
InterSystems has addressed security vulnerabilities that impact applications using OAuth2 Client configurations on InterSystems IRIS, InterSystems IRIS for Health, HealthShare, HealthShare HealthConnect, TrakCare, Caché, and Ensemble. Remediation steps and additional guidance documentation are available from the InterSystems Worldwide Response Center (WRC).
02 Apr 2025
Product & Versions Affected Explicit Requirements DP-439207 InterSystems IRIS® data platform 2024.3 (AIX) AIX installations Using JSON processing and Unicode non-Latin-1 character sets DP-439280 InterSystems IRIS 2024.3 (containers with IntegratedML) IntegratedML Containers using TensorFlow
04 Mar 2025
This problem affects the following products:
04 Mar 2025
This problem affects the following products:

Passez à l'étape suivante

Nous serions ravis d'échanger avec vous. Remplissez les champs suivants et nous vous recontacterons.
*Champs obligatoires
Veuillez remplir tous les champs obligatoires*
*Champs obligatoires
Veuillez remplir tous les champs obligatoires*
** En cochant cette case, vous consentez à recevoir des actualités, des mises à jour et toute autre information à objectif marketing liés aux produits et événements actuels et futurs d'InterSystems. En outre, vous consentez à ce que vos coordonnées professionnelles soient saisies dans notre solution CRM hébergée aux États-Unis, mais conservées conformément aux lois applicables en matière de protection des données.