Skip to content
Effectuez une recherche pour en savoir plus sur les produits et solutions InterSystems, les offres d'emploi, etc.

Advisory: Some FHIR Queries that use _include and _revinclude Fail Silently

March 1, 2022 – Advisory: Some FHIR Queries that use _include and _revinclude Fail Silently

This problem affects the following products:

  • HealthShare Unified Care Record 2019.1.x, 2019.2, 2020.1, 2020.2
  • IRIS for Health 2019.4, 2020.1, 2020.2, 2020.3, 2020.4, 2021.1

This advisory encompasses two distinct issues related to the use of _include and _revinclude search parameters in FHIR queries:

  1. Some FHIR resource references allow a reference to a resource of any type. The indices for these references were not being calculated properly, resulting in failed searches when using _include and _revinclude.
  2. An improperly formatted query using _include or _revinclude fails silently rather than reporting an error to the client.

In both cases, the returned resultset does not include the requested included resources, but the client is unaware of the error.

The correction for this defect is identified as IF-1899/HSIEC-6196 and was addressed starting in HealthShare 2021.1 and InterSystems IRIS for Health 2021.2. For more information and available fixes for this issue, please refer to IF-1899/HSIEC-6196 when speaking with the Worldwide Response Center (WRC).

Latest Alerts & Advisories

17 Apr 2025
InterSystems has addressed security vulnerabilities that impact applications using OAuth2 Client configurations on InterSystems IRIS, InterSystems IRIS for Health, HealthShare, HealthShare HealthConnect, TrakCare, Caché, and Ensemble. Remediation steps and additional guidance documentation are available from the InterSystems Worldwide Response Center (WRC).
02 Apr 2025
Product & Versions Affected Explicit Requirements DP-439207 InterSystems IRIS® data platform 2024.3 (AIX) AIX installations Using JSON processing and Unicode non-Latin-1 character sets DP-439280 InterSystems IRIS 2024.3 (containers with IntegratedML) IntegratedML Containers using TensorFlow
04 Mar 2025
This problem affects the following products:
04 Mar 2025
This problem affects the following products:

Passez à l'étape suivante

Nous serions ravis d'échanger avec vous. Remplissez les champs suivants et nous vous recontacterons.
*Champs obligatoires
Veuillez remplir tous les champs obligatoires*
*Champs obligatoires
Veuillez remplir tous les champs obligatoires*
** En cochant cette case, vous consentez à recevoir des actualités, des mises à jour et toute autre information à objectif marketing liés aux produits et événements actuels et futurs d'InterSystems. En outre, vous consentez à ce que vos coordonnées professionnelles soient saisies dans notre solution CRM hébergée aux États-Unis, mais conservées conformément aux lois applicables en matière de protection des données.