Skip to content
Effectuez une recherche pour en savoir plus sur les produits et solutions InterSystems, les offres d'emploi, etc.

Alert: Missing Locks after ECP Database Server Restart or Failover

October 26, 2021 – Alert: Missing Locks after ECP Database Server Restart or Failover

InterSystems has corrected a defect that can violate application locking guarantees in a distributed cache cluster (ECP configuration), which can lead to application integrity issues. This defect affects:

  • All major releases and maintenance versions of InterSystems IRIS and InterSystems IRIS for Health, starting with 2020.1.0

The defect can only occur when an application server successfully performs ECP recovery after a restart or failover of the data server, as follows:

  • If processes running on the application server hold more than 255 total locks on databases hosted on the data server at the time of the restart or failover, some of these locks may not be recorded in the data server’s lock table.
  • Because the data server manages the distribution of locks across the cluster, this makes it possible for a process on another application server or the data server itself to concurrently acquire a lock that conflicts with one of the locks held by the application server, which can lead to application integrity issues.

For more information on locking and concurrency, see Locking and Concurrency Control.

The correction for this defect is identified as SML2930 and will be included in all future product releases, including InterSystems IRIS and InterSystems IRIS for Health 2020.1.2 and 2021.1.1. It is also available via Ad hoc distribution from the InterSystems Worldwide Response Center (WRC).

Note to HealthShare Customers Although the HealthShare family of products does not make direct use of distributed cache clusters, HealthShare does support using them to access data on a separate instance of HealthShare. Customers making use of this feature will need to review their configurations to determine whether they could be impacted by this defect.

If you have any questions regarding this alert, please contact the Worldwide Response Center.

Latest Alerts & Advisories

17 Apr 2025
InterSystems has addressed security vulnerabilities that impact applications using OAuth2 Client configurations on InterSystems IRIS, InterSystems IRIS for Health, HealthShare, HealthShare HealthConnect, TrakCare, Caché, and Ensemble. Remediation steps and additional guidance documentation are available from the InterSystems Worldwide Response Center (WRC).
02 Apr 2025
Product & Versions Affected Explicit Requirements DP-439207 InterSystems IRIS® data platform 2024.3 (AIX) AIX installations Using JSON processing and Unicode non-Latin-1 character sets DP-439280 InterSystems IRIS 2024.3 (containers with IntegratedML) IntegratedML Containers using TensorFlow
04 Mar 2025
This problem affects the following products:
04 Mar 2025
This problem affects the following products:

Passez à l'étape suivante

Nous serions ravis d'échanger avec vous. Remplissez les champs suivants et nous vous recontacterons.
*Champs obligatoires
Veuillez remplir tous les champs obligatoires*
*Champs obligatoires
Veuillez remplir tous les champs obligatoires*
** En cochant cette case, vous consentez à recevoir des actualités, des mises à jour et toute autre information à objectif marketing liés aux produits et événements actuels et futurs d'InterSystems. En outre, vous consentez à ce que vos coordonnées professionnelles soient saisies dans notre solution CRM hébergée aux États-Unis, mais conservées conformément aux lois applicables en matière de protection des données.