Skip to content
Use the search to find information about InterSystems products and solutions, career opportunities, and more.

Advisory: Potential Data Integrity Issue with HealthShare FHIR Resource Searches against the FHIR Repository

June 4, 2020 – Advisory: Potential Data Integrity Issue with HealthShare FHIR Resource Searches against the FHIR Repository

InterSystems has corrected a defect that can lead to missing resource data in FHIR search results.

This problem exists for:

  • HealthShare Unified Care Record 2020.1.0 b7015

This defect occurs due to an incorrect resource being deleted from the search index. Subsequent FHIR Resource requests against the FHIR Repository may return incomplete results due to that missing index. Any type of FHIR resource data can be lost, and depending on when the defect occurs, the same FHIR request could return different result sets.

This defect only affects FHIR resources at the HealthShare ODS. CDA documents and HealthShare SDA are not affected; data displayed in the Clinical Viewer or retrieved by APIs, other than the FHIR APIs, are also not affected.

The correction for this defect is identified as IF-766,and will be included in all future HealthShare product releases. The fix is also available via Ad Hoc change file (patch) and the HealthShare Unified Care Record kit on the WRC Software Distribution site has been updated to 2020.1.0 b7017 and contains this fix.

If you have any questions regarding this advisory, please contact the Worldwide Response Center (WRC).

RELATED TOPICS

Latest Alerts & Advisories

17 Apr 2025
InterSystems has addressed security vulnerabilities that impact applications using OAuth2 Client configurations on InterSystems IRIS, InterSystems IRIS for Health, HealthShare, HealthShare HealthConnect, TrakCare, Caché, and Ensemble. Remediation steps and additional guidance documentation are available from the InterSystems Worldwide Response Center (WRC).
02 Apr 2025
Product & Versions Affected Explicit Requirements DP-439207 InterSystems IRIS® data platform 2024.3 (AIX) AIX installations Using JSON processing and Unicode non-Latin-1 character sets DP-439280 InterSystems IRIS 2024.3 (containers with IntegratedML) IntegratedML Containers using TensorFlow
04 Mar 2025
This problem affects the following products:
04 Mar 2025
This problem affects the following products: