Skip to content
Pesquise para saber mais sobre produtos e soluções da InterSystems, oportunidades de carreira e muito mais.

Advisory: Windows EnableVSSBackup Setting Disabled on Upgrade

September 19, 2019 – Advisory: Windows EnableVSSBackup Setting Disabled on Upgrade

InterSystems has corrected a defect that could lead to invalid backups on Windows platforms. The defect causes upgrades to disable the EnableVSSBackup setting. By default, EnableVSSBackup is enabled (value set to 1) and the upgrade sets its value to 0. Windows VSS backups taken with this setting disabled may contain invalid CACHE.DAT files.

This problem is limited to Windows platforms on the following versions:

  • Caché and Ensemble 2018.1.0, 2018.1.1, and 2018.1.2
  • HealthShare Health Connect (HSAP) 15.032 on Core versions 2018.1.0, 2018.1.1, and 2018.1.2
  • HealthShare 2019.1 (Unified Care Record, Patient Index, Health Insight, Personal Community, and Provider Directory) on Core version 2018.1.2
  • HealthShare 2018.1 (Information Exchange, Patient Index, Health Insight, and Personal Community) on Core versions 2018.1.1 or 2018.1.0

The defect only occurs if you are upgrading to a version listed above. Once you have upgraded to an affected version, you must manually enable the setting; otherwise, it will be disabled on future upgrades, even when upgrading to versions containing the correction.

For customers using Windows VSS backups, InterSystems recommends enabling this setting on any 2018.1 instances of Caché or Ensemble. Once you have enabled the setting, future upgrades (including to affected versions) will preserve its value.

You can enable the EnableVSSBackup setting either in the Management Portal or using the cache.cpf file:

In the Management Portal

  • On the Startup Settings page (System Administration >Configuration > Additional Settings > Startup), click the Edit link for EnableVSSBackup. This displays the Edit: EnableVSSBackup page.
  • On this page, select the EnableVSSBackup checkbox and the click the Save button.

This enables the feature immediately.

Using the cache.cpf File

  • In the cache.cpf file in the installation directory, in the [Startup] section, modify the EnableVSSBackup line:EnableVSSBackup=1
  • In the Terminal, in the %SYS namespace, activate the CPF changes with the following call:%SYS>set status = ##class(Config.CPF).Activate()

For more information on the Activate class method of the Config.CPF class, see the class reference for your instance of Caché or Ensemble.

For More Information

The correction for this defect is identified as STC3008, which will be included in all future releases. If you have any questions regarding this advisory, please contact the Worldwide Response Center.

RELATED TOPICS

Latest Alerts & Advisories

Aug 15, 2024
InterSystems has corrected a defect that can cause database corruption or errors with multi-volume databases under extremely rare circumstances. Only databases that have been truncated are at risk.
Jul 24, 2024
There are four alerts in the HS2024-03 Alert Communication. A summary of each alert is shown below. Details for each alert are contained in the linked document.
Jun 24, 2024
Broadcom recently announced a problem that can cause data consistency errors in database applications. The Broadcom article is available here:
May 30, 2024
Beginning with the release of InterSystems IRIS® data platform 2022.3, InterSystems corrected the license enforcement mechanism to include REST and SOAP requests. Due to this change, environments with non-core-based licenses that use REST or SOAP may experience greater license utilization after upgrading. To determine if this advisory applies to your InterSystems license, follow the instructions in the FAQ linked below.
Apr 30, 2024
InterSystems has corrected an issue that can cause a small number of SQL queries to return incorrect results. See below for the specifics on impacted queries.
Apr 08, 2024
InterSystems has encountered a defect that causes some upgrades of HealthShare® Health Connect to fail. This only affects instances that are not licensed for the use of FHIR® and that have interoperability-enabled namespaces. Under these conditions, the upgrade fails with an error.
Mar 19, 2024
In evaluating an IBM Support notification, InterSystems has determined a potential impact for our customers. The notification in question is:
Feb 27, 2024
There is 1 alert in the HealthShare HS2024-limited Alert communication. An alert summary for the issue is shown is in the table below. Details for the alert are contained in the attached document: HS2024 Limited Communication.
Feb 01, 2024
There are 2 alerts in the HealthShare HS2024-02 Alert communication. An alert summary for each issue is shown is in the table below. Details for each alert are contained in the attached document: HS2024-02-Communication.