Skip to content
Busque para obtener información sobre los productos y soluciones de InterSystems, las oportunidades de carrera y más.

Advisory: Calculation Error in InterSystems Optimization (Itanium Platforms only)

May 21, 2014 - Advisory: Calculation Error in InterSystems Optimization (Itanium Platforms only)

InterSystems has corrected a defect that causes incorrect calculation on Itanium platforms. The defect is present in InterSystems assembly optimizations targeted to Itanium platforms.

This defect is present on all currently released versions of Caché, Ensemble, and HealthShare. It is limited to Itanium platforms.

Specifically, the problem can occur when adding to a local or global variable that has the value 2147483647 (that is, 2**31-1). The problem does not occur for every such operation but depends on preceding activity. See the following example:

>set test=2147483646

>write test set test=test+1

2147483646

>write test set test=test+1

2147483647

>write test

6917529029788565504

Furthermore, it is adding to the value that fails so even an operation such as

>if test+1>xyz …

may experience the failure.

The correction for this defect is identified as JLC1792 and will be included in upcoming release 2014.1.2 of Caché, Ensemble, and HealthShare. It is also available via Ad Hoc distribution from InterSystems Worldwide Response Center (WRC). If you have any questions regarding this advisory, please contact the Worldwide Response Center.

Latest Alerts & Advisories

Aug 15, 2024
InterSystems has corrected a defect that can cause database corruption or errors with multi-volume databases under extremely rare circumstances. Only databases that have been truncated are at risk.
Jul 24, 2024
There are four alerts in the HS2024-03 Alert Communication. A summary of each alert is shown below. Details for each alert are contained in the linked document.
Jun 24, 2024
Broadcom recently announced a problem that can cause data consistency errors in database applications. The Broadcom article is available here:
May 30, 2024
Beginning with the release of InterSystems IRIS® data platform 2022.3, InterSystems corrected the license enforcement mechanism to include REST and SOAP requests. Due to this change, environments with non-core-based licenses that use REST or SOAP may experience greater license utilization after upgrading. To determine if this advisory applies to your InterSystems license, follow the instructions in the FAQ linked below.
Apr 08, 2024
InterSystems has encountered a defect that causes some upgrades of HealthShare® Health Connect to fail. This only affects instances that are not licensed for the use of FHIR® and that have interoperability-enabled namespaces. Under these conditions, the upgrade fails with an error.
Mar 19, 2024
In evaluating an IBM Support notification, InterSystems has determined a potential impact for our customers. The notification in question is:
Feb 27, 2024
There is 1 alert in the HealthShare HS2024-limited Alert communication. An alert summary for the issue is shown is in the table below. Details for the alert are contained in the attached document: HS2024 Limited Communication.
Feb 01, 2024
There are 2 alerts in the HealthShare HS2024-02 Alert communication. An alert summary for each issue is shown is in the table below. Details for each alert are contained in the attached document: HS2024-02-Communication.
Jan 17, 2024
This problem affects the following products: