Alert: Caché Online Backup and Journal Restore.

October 11, 2016 – Alert: Caché Online Backup and Journal Restore.

InterSystems has corrected a defect that may result in missing updates when utilizing Caché online backup.

This defect is present in all Caché and Ensemble versions 2015.1.x, 2015.2.x and 2016.1.x, and all HealthShare distributions based on those versions.  It affects all platforms and operating systems except backups of OpenVMS cluster databases.

The risk does not exist for Mirror Catchup applied to mirrored databases restored from Caché online backup.

The risk only exists when restoring from Caché online backup and applying journal files.  You are at risk of having missing updates if the following are all true:

  • The backup was created by Caché online backup in a product version where this defect is present.
  • The journal is restored using the default option to start at the journal marker set by Caché backup.

This applies for all forms of Caché online backup: full, cumulative, incremental and “Legacy Concurrent External”.

The risk can be avoided by applying journals from the beginning of the journal file that was switched to at the start of the backup, rather than accepting the default of starting from the journal marker position.

The correction for this defect is identified as RJF229.  It will be included in all future releases of Caché, Ensemble, and HealthShare.  The correction is also available via Ad Hoc distribution from InterSystems Worldwide Response Center (WRC).  If you have any questions regarding this advisory, please contact the Worldwide Response Center.

RELATED TOPICS

最新警报和通知

Aug 21, 2024
InterSystems 已修复了一个缺陷,在极少数情况下,该缺陷可能导致多卷数据库出现数据库损坏或 错误。只有被截断的数据库才存在风险。
Jun 03, 2024
从发布InterSystems IRIS®数据平台2022.3开始,InterSystems修改了许可证强制执行机制,以包括REST和SOAP请求。由于这种变化,在升级后,使用REST或SOAP的非处理器核数的许可证环境下,用户可能会遇到更高的许可证消耗。要确定此警报是否适用于您的InterSystems许可证,请按照下面链接的FAQ中的说明进行操作。
May 01, 2024
InterSystems has corrected an issue that can cause a small number of SQL queries to return incorrect results. See below for the specifics on impacted queries.
Nov 14, 2023
There are 10 alerts in the HealthShare HS2023-02 Alert communication. An alert summary for each issue is shown is in the table below. Details for each alert are contained in the attached document: HS2023-02-Communication.
Jun 17, 2023
InterSystems 已纠正导致进程内存使用量增加的缺陷。
May 11, 2023
InterSystems已经解决了影响Caché、Ensemble、HealthShare、InterSystems IRIS、InterSystems IRIS for Health、HealthShare HealthConnect和TrakCare的安全漏洞。 这些漏洞影响到InterSystems所有版本的产品。
Apr 28, 2023
InterSystems 已修复了一个缺陷,该缺陷可能会导致使用 IBM POWER8 或更高版本的 POWER 处理器的 AIX 系统上的数据库和Journal日志文件损坏。只有在使用数据库或Journal日志加密时才会触发此缺陷。
Apr 11, 2023
InterSystems已修复一个缺陷,该缺陷在罕见情况下会导致ECP客户端不稳定。
Apr 06, 2023
InterSystems 已修复一个导致SQL查询返回不正确结果的缺陷。该缺陷存在于以下产品和基于这些产品的任何InterSystems产品中。