October 12, 2018 – Alert: Ordering of XML Sibling Elements

InterSystems has corrected a defect that can cause a reordering of sibling elements in an XML document. This issue is limited to sibling elements that are represented in the database as objects in a relationship.

This problem exists on all platforms for the following products:

  • InterSystems IRIS Data Platform 2018.1.0 and above
  • InterSystems IRIS for Health 2018.1.2
  • Caché and Ensemble 2017.2.0 and above
  • Health Connect/HSAP based on Caché/Ensemble 2017.2.0 and above

Note: HealthShare functionality has been reviewed and is not impacted by this defect.This includes pre-built Health Connect functions; only customers that have created their own functions could be affected.

How the Problem Occurs

When an XML document makes a round trip from XML to InterSystems objects and then back to XML, the ordering of sibling elements is not preserved. This is a violation of the XML Infoset specification, which defines elements as being ordered. If your application handles XML documents in this way, you may encounter unexpected results.

Availability of Corrections

The corrections for these defects are identified as TRW1621 and MAK4992. After installing these corrections, it is necessary to recompile all application routines and classes. These corrections are available via Ad hoc distribution from the InterSystems Worldwide Response Center (WRC).

If you have any questions regarding this alert, please contact the Worldwide Response Center.

最新警报和通知

Feb 22, 2025
InterSystems 已纠正了两个可能导致少数 SQL 查询返回不正确结果的问题。 此外,InterSystems 还纠正了日期/时间数据类型处理中的不一致性,对于依赖于先前不一致性行为的现有应用程序来说,这种不一致性可能会导致不同的、意想不到的但正确的结果。
Feb 19, 2025
InterSystems 已修复一个缺陷,该缺陷导致在使用特定 $LIST 语法时引入无效的数据库和日志记录。 遇到这种缺陷的可能性很低,但对运营的影响可能很大。
Oct 09, 2024
InterSystems 已经解决了影响 InterSystems IRIS、InterSystems IRIS for Health、HealthShare、HealthShare HealthConnect、TrakCare、Caché 和 Ensemble 的 Web 网关和 CSP 网关的安全漏洞。可从 InterSystems 全球响应中心 (WRC) 获取补救步骤和其他指导文件。在讨论本通知时,请参考 "SVR2024A"。 如需修复帮助,请联系您的应用程序提供商或 InterSystems 全球响应中心。
Aug 21, 2024
InterSystems 已修复了一个缺陷,在极少数情况下,该缺陷可能导致多卷数据库出现数据库损坏或 错误。只有被截断的数据库才存在风险。
Jun 03, 2024
从发布InterSystems IRIS®数据平台2022.3开始,InterSystems修改了许可证强制执行机制,以包括REST和SOAP请求。由于这种变化,在升级后,使用REST或SOAP的非处理器核数的许可证环境下,用户可能会遇到更高的许可证消耗。要确定此警报是否适用于您的InterSystems许可证,请按照下面链接的FAQ中的说明进行操作。
May 01, 2024
InterSystems has corrected an issue that can cause a small number of SQL queries to return incorrect results. See below for the specifics on impacted queries.
Nov 14, 2023
There are 10 alerts in the HealthShare HS2023-02 Alert communication. An alert summary for each issue is shown is in the table below. Details for each alert are contained in the attached document: HS2023-02-Communication.
Jun 17, 2023
InterSystems 已纠正导致进程内存使用量增加的缺陷。
May 11, 2023
InterSystems已经解决了影响Caché、Ensemble、HealthShare、InterSystems IRIS、InterSystems IRIS for Health、HealthShare HealthConnect和TrakCare的安全漏洞。 这些漏洞影响到InterSystems所有版本的产品。