Skip to content
搜索以了解InterSystems产品和解决方案,职业机会等。

Alert: Potential Integrity Issue with Mirroring

July 6, 2016 – Alert: Potential Integrity Issue with Mirroring

InterSystems has corrected a defect with Mirroring that can impact data integrity.

The defect is present in all released versions Caché, Ensemble, and HealthShare beginning with 2015.2.0. It is present for all platforms and affects both failover and asynchronous mirroring configurations.

The nature of the defect is that updates may be skipped when journals are applied to a non-primary system. The defect is only triggered under certain unusual conditions when a non-primary mirror member is starting or reconnecting.

InterSystems recommends, in addition to obtaining the correction, that at-risk systems be checked for impact. There are two methods to do this:

  1. A utility, available via FTP here, can be used to scan a series of cconsole.log files and determine that a system has not been impacted. To ensure a complete check the routine must scan all cconsole.log files generated since a system was upgraded to 2015.2+. Load it in any namespace and invoke it interactively with ‘do ^SML2330Alert’.
  2. The ^DATACHECK utility can be used to check that destination and source systems are in sync.

If either check indicates a problem, please contact InterSystems Worldwide Response Center (WRC) for further assistance. The affected mirror member may need to be rebuilt; information on rebuilding a mirror member can be found here.

The correction for this defect is identified as SML2330. It will be included in all future product releases including the upcoming 2015.2.4 and 2016.1.2 maintenance distributions. It is also available via ad hoc distribution as a patched routine. If you have any questions regarding this alert, please contact InterSystems Worldwide Response Center.

最新警报和通知

Aug 21, 2024
InterSystems 已修复了一个缺陷,在极少数情况下,该缺陷可能导致多卷数据库出现数据库损坏或 错误。只有被截断的数据库才存在风险。
Jun 03, 2024
从发布InterSystems IRIS®数据平台2022.3开始,InterSystems修改了许可证强制执行机制,以包括REST和SOAP请求。由于这种变化,在升级后,使用REST或SOAP的非处理器核数的许可证环境下,用户可能会遇到更高的许可证消耗。要确定此警报是否适用于您的InterSystems许可证,请按照下面链接的FAQ中的说明进行操作。
May 01, 2024
InterSystems has corrected an issue that can cause a small number of SQL queries to return incorrect results. See below for the specifics on impacted queries.
Nov 14, 2023
There are 10 alerts in the HealthShare HS2023-02 Alert communication. An alert summary for each issue is shown is in the table below. Details for each alert are contained in the attached document: HS2023-02-Communication.
Jun 17, 2023
InterSystems 已纠正导致进程内存使用量增加的缺陷。
May 11, 2023
InterSystems已经解决了影响Caché、Ensemble、HealthShare、InterSystems IRIS、InterSystems IRIS for Health、HealthShare HealthConnect和TrakCare的安全漏洞。 这些漏洞影响到InterSystems所有版本的产品。
Apr 28, 2023
InterSystems 已修复了一个缺陷,该缺陷可能会导致使用 IBM POWER8 或更高版本的 POWER 处理器的 AIX 系统上的数据库和Journal日志文件损坏。只有在使用数据库或Journal日志加密时才会触发此缺陷。
Apr 11, 2023
InterSystems已修复一个缺陷,该缺陷在罕见情况下会导致ECP客户端不稳定。
Apr 06, 2023
InterSystems 已修复一个导致SQL查询返回不正确结果的缺陷。该缺陷存在于以下产品和基于这些产品的任何InterSystems产品中。