Alert: Dejournaling Problem May Result in Missing Updates

July 16, 2014 - Alert: Dejournaling Problem May Result in Missing Updates

InterSystems has corrected a defect that can impact data integrity. The defect is present in Caché, Ensemble, and HealthShare version 2013.1.0 and later.

This defect may cause some database modifications to be missed when journal files are applied to a database. The problem may occur on systems that are the target of data replication (via mirroring or shadowing), on systems recovering after an unplanned outage, or when databases are being restored from journal files.

The problem occurs rarely and exact circumstances are dependent on internal “race conditions” between several processes, so are not easily characterized externally. There is no way to tell if a system has been affected by this defect. However, on systems using mirroring or shadowing, the DATACHECK utility can be used to see if the destination system accurately reflects the source.

The correction for this defect is identified as HYY1943. It will be included in all future releases of Caché, Ensemble, and HealthShare. The first release to include the correction will be 2014.1.2 which will be available no later than July 31st. The correction is also available via Ad Hoc distribution from InterSystems Worldwide Response Center (WRC). If you have any questions regarding this advisory, please contact the Worldwide Response Center.

Latest Alerts & Advisories

15 Aug 2024
InterSystems has corrected a defect that can cause database corruption or errors with multi-volume databases under extremely rare circumstances. Only databases that have been truncated are at risk.
24 Jul 2024
There are four alerts in the HS2024-03 Alert Communication. A summary of each alert is shown below. Details for each alert are contained in the linked document.
24 Jun 2024
Broadcom recently announced a problem that can cause data consistency errors in database applications. The Broadcom article is available here:
30 May 2024
Beginning with the release of InterSystems IRIS® data platform 2022.3, InterSystems corrected the license enforcement mechanism to include REST and SOAP requests. Due to this change, environments with non-core-based licenses that use REST or SOAP may experience greater license utilization after upgrading. To determine if this advisory applies to your InterSystems license, follow the instructions in the FAQ linked below.
01 May 2024
InterSystems has corrected an issue that can cause a small number of SQL queries to return incorrect results. See below for the specifics on impacted queries.
08 Apr 2024
InterSystems has encountered a defect that causes some upgrades of HealthShare® Health Connect to fail. This only affects instances that are not licensed for the use of FHIR® and that have interoperability-enabled namespaces. Under these conditions, the upgrade fails with an error.
19 Mar 2024
In evaluating an IBM Support notification, InterSystems has determined a potential impact for our customers. The notification in question is:
27 Feb 2024
There is 1 alert in the HealthShare HS2024-limited Alert communication. An alert summary for the issue is shown is in the table below. Details for the alert are contained in the attached document: HS2024 Limited Communication.
01 Feb 2024
There are 2 alerts in the HealthShare HS2024-02 Alert communication. An alert summary for each issue is shown is in the table below. Details for each alert are contained in the attached document: HS2024-02-Communication.