Skip to content
Keressen, hogy többet megtudjon az InterSystems termékeiről és megoldásairól, karrierlehetőségekről és még sok másról.

Alert: Large ODBC Query Results Incomplete

November 3, 2015 – Alert: Large ODBC Query Results Incomplete

InterSystems has corrected a defect with the Caché ODBC driver that can result in incomplete query results. The problem can occur when the total size of all rows returned would exceed 4KB. There is no indication that the failure has occurred. Results greater than 4KB are truncated.

This defect exists only in the Caché ODBC driver that is distributed with versions 2015.2.0 and 2015.2.1 of Caché, Ensemble, and HealthShare. The risk is present for all platforms and operating systems.

The corrections for this defect are identified as JCN1662 and JCN1665. They will be included in all future releases of Caché, Ensemble, and HealthShare.

Caché ODBC drivers are designed to be upward and backward compatible. Until corrected Caché ODBC drivers for 2015.2 are available, drivers from older versions can be used to avoid this issue. Drivers for older versions are available in the download area of the Worldwide Response Center (WRC) application.

If you have any questions regarding this advisory, or need assistance with obtaining and installing drivers, please contact the Worldwide Response Center.

Latest Alerts & Advisories

Aug 15, 2024
InterSystems has corrected a defect that can cause database corruption or errors with multi-volume databases under extremely rare circumstances. Only databases that have been truncated are at risk.
Jul 24, 2024
There are four alerts in the HS2024-03 Alert Communication. A summary of each alert is shown below. Details for each alert are contained in the linked document.
Jun 24, 2024
Broadcom recently announced a problem that can cause data consistency errors in database applications. The Broadcom article is available here:
May 30, 2024
Beginning with the release of InterSystems IRIS® data platform 2022.3, InterSystems corrected the license enforcement mechanism to include REST and SOAP requests. Due to this change, environments with non-core-based licenses that use REST or SOAP may experience greater license utilization after upgrading. To determine if this advisory applies to your InterSystems license, follow the instructions in the FAQ linked below.
May 01, 2024
InterSystems has corrected an issue that can cause a small number of SQL queries to return incorrect results. See below for the specifics on impacted queries.
Apr 08, 2024
InterSystems has encountered a defect that causes some upgrades of HealthShare® Health Connect to fail. This only affects instances that are not licensed for the use of FHIR® and that have interoperability-enabled namespaces. Under these conditions, the upgrade fails with an error.
Mar 19, 2024
In evaluating an IBM Support notification, InterSystems has determined a potential impact for our customers. The notification in question is:
Feb 27, 2024
There is 1 alert in the HealthShare HS2024-limited Alert communication. An alert summary for the issue is shown is in the table below. Details for the alert are contained in the attached document: HS2024 Limited Communication.
Feb 01, 2024
There are 2 alerts in the HealthShare HS2024-02 Alert communication. An alert summary for each issue is shown is in the table below. Details for each alert are contained in the attached document: HS2024-02-Communication.