Skip to content
Telusuri untuk mempelajari tentang produk dan solusi InterSystems, peluang karier, dan banyak lagi.

Advisory: Deletion of Streamlets Causes System Index Errors

This problem affects the following products:

  • HealthShare Unified Care Record:  2022.1, 2022.2, 2023.1, 2023.1.1, 2023.2

If an Administrator deletes SDA streamlets directly from the HS.SDA3.Streamlet.* globals, a failure state can be created with the System Index or a System Index enabled client.

Please note that direct deletion of globals bypasses the notification processes that delete metadata from Edge Gateway and System Index tables and is not a supported procedure.

This can result in one of two problems:

  1. If the streamlets are deleted after upgrading to an affected version from 2021.2 or older and before enabling System Index, the polling processes on System Index will hang on the deleted streamlet ID keys.
  2. If streamlets are deleted from the Edge Gateway, after the metadata has been loaded into System Index, retrievals for those deleted streamlets will fail fatally. For patient retrieves, no data from the Edge Gateway will be returned. For streaming feeds such as with Health Insight, this will result in the polling process for the Edge Gateway to freeze.

Affected customers may contact InterSystems Worldwide Response Center (WRC) for assistance regarding this advisory and reference HSDD-2160.
Fixes for this issue are available for versions 2022.2, 2023.1, 2023.1.1, and HS2023.2

RELATED TOPICS

Latest Alerts & Advisories

15 Agustus, 2024
InterSystems has corrected a defect that can cause database corruption or errors with multi-volume databases under extremely rare circumstances. Only databases that have been truncated are at risk.
25 Juli, 2024
There are four alerts in the HS2024-03 Alert Communication. A summary of each alert is shown below. Details for each alert are contained in the linked document.
24 Juni, 2024
Broadcom recently announced a problem that can cause data consistency errors in database applications. The Broadcom article is available here:
30 Mei, 2024
Beginning with the release of InterSystems IRIS® data platform 2022.3, InterSystems corrected the license enforcement mechanism to include REST and SOAP requests. Due to this change, environments with non-core-based licenses that use REST or SOAP may experience greater license utilization after upgrading. To determine if this advisory applies to your InterSystems license, follow the instructions in the FAQ linked below.
01 Mei, 2024
InterSystems has corrected an issue that can cause a small number of SQL queries to return incorrect results. See below for the specifics on impacted queries.
08 April, 2024
InterSystems has encountered a defect that causes some upgrades of HealthShare® Health Connect to fail. This only affects instances that are not licensed for the use of FHIR® and that have interoperability-enabled namespaces. Under these conditions, the upgrade fails with an error.
19 Maret, 2024
In evaluating an IBM Support notification, InterSystems has determined a potential impact for our customers. The notification in question is:
27 Februari, 2024
There is 1 alert in the HealthShare HS2024-limited Alert communication. An alert summary for the issue is shown is in the table below. Details for the alert are contained in the attached document: HS2024 Limited Communication.
01 Februari, 2024
There are 2 alerts in the HealthShare HS2024-02 Alert communication. An alert summary for each issue is shown is in the table below. Details for each alert are contained in the attached document: HS2024-02-Communication.