Advisory: Users Unable to Log in After Upgrade Due to Missing Index

This problem affects the following products:

  • HealthShare Unified Care Record:  2021.2, 2022.1, 2022.2, 2023.1

In version 2021.2 of Unified Care Record, a new property was added to the user/clinician registry. After upgrading to an affected version, users may be unable to log into the system post-upgrade due to a missing index on the new property. A manual re-indexing step was added to the upgrade instructions for those versions after-the-fact.
The defect has been corrected in version 2023.2, and the relevant indices are now automatically rebuilt as part of the upgrade process.

For customers upgrading to an affected version of HealthShare, the workaround is to manually rebuild the indices after the Registry upgrade is complete by running the following command in terminal in the Registry namespace:

set status=##class(HS.Registry.Person.UserLoginID).%BuildIndices()

write status

There is no ad hoc patch associated with this advisory.

If you have any questions regarding this issue, please contact InterSystems Worldwide Response Center (WRC) for assistance and reference HSIEO-6028.

RELATED TOPICS

Latest Alerts & Advisories

15 Agustus, 2024
InterSystems has corrected a defect that can cause database corruption or errors with multi-volume databases under extremely rare circumstances. Only databases that have been truncated are at risk.
25 Juli, 2024
There are four alerts in the HS2024-03 Alert Communication. A summary of each alert is shown below. Details for each alert are contained in the linked document.
24 Juni, 2024
Broadcom recently announced a problem that can cause data consistency errors in database applications. The Broadcom article is available here:
30 Mei, 2024
Beginning with the release of InterSystems IRIS® data platform 2022.3, InterSystems corrected the license enforcement mechanism to include REST and SOAP requests. Due to this change, environments with non-core-based licenses that use REST or SOAP may experience greater license utilization after upgrading. To determine if this advisory applies to your InterSystems license, follow the instructions in the FAQ linked below.
01 Mei, 2024
InterSystems has corrected an issue that can cause a small number of SQL queries to return incorrect results. See below for the specifics on impacted queries.
08 April, 2024
InterSystems has encountered a defect that causes some upgrades of HealthShare® Health Connect to fail. This only affects instances that are not licensed for the use of FHIR® and that have interoperability-enabled namespaces. Under these conditions, the upgrade fails with an error.
19 Maret, 2024
In evaluating an IBM Support notification, InterSystems has determined a potential impact for our customers. The notification in question is:
27 Februari, 2024
There is 1 alert in the HealthShare HS2024-limited Alert communication. An alert summary for the issue is shown is in the table below. Details for the alert are contained in the attached document: HS2024 Limited Communication.
01 Februari, 2024
There are 2 alerts in the HealthShare HS2024-02 Alert communication. An alert summary for each issue is shown is in the table below. Details for each alert are contained in the attached document: HS2024-02-Communication.
17 Januari, 2024
This problem affects the following products: