Skip to content
Sök för att lära dig mer om InterSystems produkter och lösningar, karriärmöjligheter med mera.

Advisory: AIX Memory Leak

In evaluating an IBM Support notification, InterSystems has determined a potential impact for our customers. The notification in question is:

Memory Leak in std::string for programs built with xlclang++ 16.1.0 in the presence of the 17.1.1 libc++.a

This issue affects versions 2022.x and 2023.x of:

  • InterSystems IRIS® data platform
  • InterSystems IRIS for Health™
  • HealthShare® Health Connect

It also affects other InterSystems products based on the InterSystems IRIS family of products.
As described in the notification, the potential exists for a memory leak, which can eventually impact application functionality. The amount of memory leaked is minimal but operational impact is hard to predict, as it depends on implementation decisions. To date, InterSystems has received no reports from customers because of this defect.

InterSystems recommends the following actions, depending on InterSystems IRIS, InterSystems IRIS for Health™, and HealthShare® Health Connect versions:

Version

Action

Prior to 2022.xNo exposure.

2022.x

Exposure depends on AIX updates.
Do not apply AIX updates referenced in IBM notification linked above.
(This primarily means AIX 7.3 TL2). If already applied, monitor for problem and if impacted contact InterSystems for remedial change.

2023.x

Exposed.
Monitor for problem and if impacted contact InterSystems for remedial change
2024.xNo exposure.

InterSystems has created a remediation based on IBM guidance. It is identified as CRE-7591 and is available via Ad hoc distribution. The remediation will be included in all future product releases, starting with 2022.1.5 and 2023.1.4.

If you have any questions regarding this alert, please contact the Worldwide Response Center.

Latest Alerts & Advisories

aug. 15, 2024
InterSystems has corrected a defect that can cause database corruption or errors with multi-volume databases under extremely rare circumstances. Only databases that have been truncated are at risk.
juli 24, 2024
There are four alerts in the HS2024-03 Alert Communication. A summary of each alert is shown below. Details for each alert are contained in the linked document.
juni 24, 2024
Broadcom recently announced a problem that can cause data consistency errors in database applications. The Broadcom article is available here:
maj 30, 2024
Beginning with the release of InterSystems IRIS® data platform 2022.3, InterSystems corrected the license enforcement mechanism to include REST and SOAP requests. Due to this change, environments with non-core-based licenses that use REST or SOAP may experience greater license utilization after upgrading. To determine if this advisory applies to your InterSystems license, follow the instructions in the FAQ linked below.
maj 01, 2024
InterSystems has corrected an issue that can cause a small number of SQL queries to return incorrect results. See below for the specifics on impacted queries.
apr. 08, 2024
InterSystems has encountered a defect that causes some upgrades of HealthShare® Health Connect to fail. This only affects instances that are not licensed for the use of FHIR® and that have interoperability-enabled namespaces. Under these conditions, the upgrade fails with an error.
feb. 27, 2024
There is 1 alert in the HealthShare HS2024-limited Alert communication. An alert summary for the issue is shown is in the table below. Details for the alert are contained in the attached document: HS2024 Limited Communication.
feb. 01, 2024
There are 2 alerts in the HealthShare HS2024-02 Alert communication. An alert summary for each issue is shown is in the table below. Details for each alert are contained in the attached document: HS2024-02-Communication.