Alert: Possible Data Integrity Issues after Compaction or Defragmentation

March 25, 2020 – Alert: Possible Data Integrity Issues after Compaction or Defragmentation

InterSystems has corrected two defects that, in rare circumstances, can result in data integrity corruption after running global compaction, database compaction, or database defragmentation. InterSystems recommends avoiding these utilities until after applying the corrections listed below.

1. The first defect is caused by database compaction, defragmentation, or global compaction, and can result in database corruption. If you have used one of these utilities on a database, InterSystems recommends that you perform an integrity check on it. This will identify any data corruption that has occurred. The correction is RJF424.

This defect has been observed on deployed systems and exists for the following versions:

  • All released versions of InterSystems IRIS and IRIS for Health
  • Caché/Ensemble versions beginning with 2016.2.0
  • All HealthShare products based on the above Data Platforms versions

2. The second defect may occur under extremely rare timing conditions, if processes are modifying (sets/kills) a database concurrently with database compaction or defragmentation. In this case, the processes may either make global updates that are not written to the database or access stale data. There is no way to definitively determine if this has occurred. Global compaction is unaffected by this defect. The correction is RJF423.

This second defect exists in all released versions of all InterSystems products, though it is highly unlikely to have occurred on deployed systems.

Both corrections will be included in all future product releases. They are also available by requesting an Ad hoc distribution from the InterSystems Worldwide Response Center (WRC).

If you have any questions regarding this alert, please contact the Worldwide Response Center.

 

Latest Alerts & Advisories

Aug 15, 2024
InterSystems has corrected a defect that can cause database corruption or errors with multi-volume databases under extremely rare circumstances. Only databases that have been truncated are at risk.
Jul 24, 2024
There are four alerts in the HS2024-03 Alert Communication. A summary of each alert is shown below. Details for each alert are contained in the linked document.
Jun 24, 2024
Broadcom recently announced a problem that can cause data consistency errors in database applications. The Broadcom article is available here:
May 30, 2024
Beginning with the release of InterSystems IRIS® data platform 2022.3, InterSystems corrected the license enforcement mechanism to include REST and SOAP requests. Due to this change, environments with non-core-based licenses that use REST or SOAP may experience greater license utilization after upgrading. To determine if this advisory applies to your InterSystems license, follow the instructions in the FAQ linked below.
May 01, 2024
InterSystems has corrected an issue that can cause a small number of SQL queries to return incorrect results. See below for the specifics on impacted queries.
Apr 08, 2024
InterSystems has encountered a defect that causes some upgrades of HealthShare® Health Connect to fail. This only affects instances that are not licensed for the use of FHIR® and that have interoperability-enabled namespaces. Under these conditions, the upgrade fails with an error.
Mar 19, 2024
In evaluating an IBM Support notification, InterSystems has determined a potential impact for our customers. The notification in question is:
Feb 27, 2024
There is 1 alert in the HealthShare HS2024-limited Alert communication. An alert summary for the issue is shown is in the table below. Details for the alert are contained in the attached document: HS2024 Limited Communication.
Feb 01, 2024
There are 2 alerts in the HealthShare HS2024-02 Alert communication. An alert summary for each issue is shown is in the table below. Details for each alert are contained in the attached document: HS2024-02-Communication.