Skip to content
Search to learn about InterSystems products and solutions, career opportunities, and more.

Advisory: HS.Stream Global in Edge Gateways Not Cleared After Errors

March 1, 2022 – Advisory: HS.Stream Global in Edge Gateways Not Cleared After Errors

InterSystems has corrected a defect where an unsuccessful patient registration does not clear data written to the HS.Stream global in Edge Gateway namespaces. This global can grow over time, fill up storage, and potentially cause system stability issues.

This defect affects all HealthShare Information Exchange/Unified Care Record versions up to and including HealthShare 2021.1.

Data is written to the HS.Stream global in Edge Gateway namespaces when registering a patient in the Registry. If the registration is successful, the data is cleared for that session. However, if the registration is unsuccessful, the data is not cleared. As a result, the HS.Stream global will grow, causing a potential system stability concern if it fills up the storage on the Edge Gateway's server.

Customers who frequently encounter errors in patient registration are more likely to be impacted by this issue. Routine monitoring of disk space helps to reduce the likelihood of encountering system stability issues. For information on monitoring disk space, see the HealthShare Monitoring and Operations Guide (specifically the Monitor Disk Space section).

The correction for this defect is identified as HSIEC-5002. It is available via Ad hoc change file (patch) or full kit distribution from the Worldwide Response Center (WRC). The correction ensures that the global data is cleared after errors are encountered. InterSystems recommends that customers running an affected version apply this correction. This correction was included in HealthShare 2021.2 and all future product releases.

RELATED TOPICS

Latest Alerts & Advisories

Apr 17, 2025
InterSystems has addressed security vulnerabilities that impact applications using OAuth2 Client configurations on InterSystems IRIS, InterSystems IRIS for Health, HealthShare, HealthShare HealthConnect, TrakCare, Caché, and Ensemble. Remediation steps and additional guidance documentation are available from the InterSystems Worldwide Response Center (WRC).
Apr 03, 2025
Product & Versions Affected Explicit Requirements DP-439207 InterSystems IRIS® data platform 2024.3 (AIX) AIX installations Using JSON processing and Unicode non-Latin-1 character sets DP-439280 InterSystems IRIS 2024.3 (containers with IntegratedML) IntegratedML Containers using TensorFlow
Mar 04, 2025
This problem affects the following products:
Mar 04, 2025
This problem affects the following products: